Description
- Power supply:AC230V ±10%,50Hz
- Power consumption:< 3W
- Accuracy of temperature measuring: ± 2°C
- Range of tank temperature measuring: 0 ~100 °C
- Suitable power of electrical heater: ≤ 1.5KW or ≤ 3KW (optional)
- Inputs:T1: NTC10K, B3950 sensor (≤ 135°C) for tank, (PVC cable ≤105°C),
- T2: temperature sensor, optional
- Outputs:H1 for electrical heater, R1: Relay.
- Ambient temperature :-10°C ~ 50°C.
- Water proof grade:IP40.